Malta Conformity Assessment Ltd. is recognised by the Malta Medicines Authority and the European Commission as a Notified Body under Regulation (EU) 2017/745.
Annex IX · Chapters I and IIIAnnex IX · Chapter IIAnnex XI · Part A
What we assess
01/ 03
Quality management system
Annex IX · Chapters I and III
Annex IX · Chapters I and III
Quality management system
We audit your quality management system to confirm that it covers the whole life of the device, and we keep checking it for as long as your certificate is valid.
QMS documentation and procedures
Design and development controls
Manufacturing and supplier controls
Post-market surveillance and vigilance
Surveillance and unannounced audits
Annex IX · Chapter II
Technical documentation assessment
Our reviewers assess the technical documentation that shows your device is safe and performs as intended.
Device description and specifications
General safety and performance requirements
Risk management
Clinical evaluation
Verification and validation data
Labelling and instructions for use
Annex XI · Part A
Production quality assurance
Where the regulation allows this route, we audit the quality system that governs manufacturing and final verification, confirming that devices leaving your site match what was assessed.
Production quality system
Final inspection and testing
Conformity with the documentation
Ongoing surveillance
Certificate life
What to expect once you are certified
Certification is the start of a working relationship. These are the fixed points the MDR sets for every certificate we issue.
5years
Maximum validity
Certificates are issued for up to five years and can be extended after a new assessment.
12months
Surveillance audits
We audit your quality management system at least once every twelve months.
1×per 5 years
Unannounced audits
At least once every five years we visit without notice and may check or test devices.
Your application
What an application includes
For a quality management system assessment, the MDR sets out what you send us. Having it ready shortens the review.
FR.MED.01Application form and its annexes
Manufacturer details
Name and registered place of business of the manufacturer and, where there is one, the authorised representative.
Devices covered
Information on the device or group of devices covered by the quality management system.
Quality management system
Documentation of your quality management system, including its procedures and records.
Technical documentation
The technical documentation of the devices concerned, as described in Annexes II and III of the MDR.
Post-market surveillance
Your post-market surveillance system, the post-market clinical follow-up plan where it applies, and your procedures for reporting incidents and field safety corrective actions.
Declarations
A written statement that no application for the same quality management system is lodged with another Notified Body, and a draft EU declaration of conformity.
Find your route
Which procedure applies to your device?
The MDR links each risk class to specific procedures. Choose a class to see the routes within our designation.
This is a guide, not a classification. We confirm your device’s class and route in a free pre-application meeting.
Lower riskHigher risk
1
Annex IX or Annex XI Part AQuality system or production audit
Needed only for the device’s sterile, measuring or reusable surgical aspects.
2
Limited scopeSterility, metrology or reuse
Our assessment covers those aspects of the device only.
Applies to Class I devices that are sterile, have a measuring function or are reusable surgical instruments.
Within MCA’s designation
Questions
Before you apply
Answers to the questions manufacturers ask us most. Anything else, we are happy to talk through in a meeting.
Can we move our certificate to MCA from another Notified Body?
Yes. The MDR allows a voluntary change of Notified Body. It is set out in an agreement between you, your current Notified Body where possible, and us, covering the date the old certificate stops being valid and how information is transferred.
MDR Article 58
Which Class I devices need a Notified Body?
Sterile devices, devices with a measuring function and reusable surgical instruments. Our assessment is limited to those aspects: sterility, metrology or reuse.
MDR Article 52(7)
In which language should our documentation be?
English. We review technical documentation in English.
How are fees set?
Our standard fees are published in FR.MED.165, so you can budget before you apply. After we review your pre-application form, we send you an offer.
Can we talk to you before applying?
Yes. Structured dialogue lets you ask regulatory and procedural questions before and during the assessment, using form FR.MED.206. A Notified Body cannot give consultancy on how to design or document a device, so the dialogue stays on requirements and procedure.
What if we change the device after certification?
Tell us about planned substantial changes before you make them, using the change notification form FR.MED.51. We assess whether the change affects your certificate.
MDR Annex IX, Sections 2.4 and 4.10
Start here
Talk to us before you apply
A free online meeting is the quickest way to confirm your route, your documents and the next steps.